Flowline Level Controllers and Indicators

General Purpose - Controllers for Switches: LC40
Controllers for Switches: LC40

General purpose or isolation versions with built-in intrinsic safety barriers for use with associated apparatus, the level switch controller is offered in three configurations for pump and valve control. The LC40 accepts one level switch input and provides one 10A relay. The LC41 accepts two level switch inputs and provides one latching 10A relay for automatic fill or empty control. The LC42/92 accepts three level switch inputs with one latching 10A relay output for automatic fill or empty control, and a second non-latching 10A relay for high level alarm or low level alarm. 

Fail-safe relay control of pumps or valves with 0-60 second delay. Easy setup with LED indicators for sensor, power and relay status. 

General Purpose - Controllers for Switches: LC41
Controllers for Switches: LC41

General purpose or isolation versions with built-in intrinsic safety barriers for use with associated apparatus, the level switch controller is offered in three configurations for pump and valve control. The LC40 accepts one level switch input and provides one 10A relay. The LC41 accepts two level switch inputs and provides one latching 10A relay for automatic fill or empty control. The LC42/92 accepts three level switch inputs with one latching 10A relay output for automatic fill or empty control, and a second non-latching 10A relay for high level alarm or low level alarm. 

Fail-safe relay control of pumps or valves with 0-60 second delay. Easy setup with LED indicators for sensor, power and relay status. 

General Purpose - Controllers for Switches: LC42
Controllers for Switches: LC42

General purpose or isolation versions with built-in intrinsic safety barriers for use with associated apparatus, the level switch controller is offered in three configurations for pump and valve control. The LC40 accepts one level switch input and provides one 10A relay. The LC41 accepts two level switch inputs and provides one latching 10A relay for automatic fill or empty control. The LC42/92 accepts three level switch inputs with one latching 10A relay output for automatic fill or empty control, and a second non-latching 10A relay for high level alarm or low level alarm. 

Fail-safe relay control of pumps or valves with 0-60 second delay. Easy setup with LED indicators for sensor, power and relay status. 

General Purpose - Controllers for Transmitters: LC52
Controllers for Transmitters: LC52

The general purpose AC powered tank or silo level controller displays engineering units with one 4-20 mA level transmitter, two programmable relays and an isolated 4-20 mA repeater. Relay one is configurable on a single set point. Relay two can be configured on a single set point or latched on two set points for automatic fill or empty control in simplex mode. Select this DIN rail mount controller for use with general purpose two or threewire level sensors.

Bright LED display indicates level in custom engineering units. Fail-safe relay control of pumps or valves with 0-60 second delay. Easy push button configuration of span, display and relay set points. 

Item LC52-1001 includes a 4-20mA Repeater

Intrinsically Safe - Controllers for Switches: LC92
Controllers for Switches: LC92

General purpose or isolation versions with built-in intrinsic safety barriers for use with associated apparatus, the level switch controller is offered in three configurations for pump and valve control. The LC40 accepts one level switch input and provides one 10A relay. The LC41 accepts two level switch inputs and provides one latching 10A relay for automatic fill or empty control. The LC42/92 accepts three level switch inputs with one latching 10A relay output for automatic fill or empty control, and a second non-latching 10A relay for high level alarm or low level alarm. 

Fail-safe relay control of pumps or valves with 0-60 second delay. Easy setup with LED indicators for sensor, power and relay status.